Your Subtitle text

Thermometer Calibrators

    TEL-TRU CHECK-TEMP CALIBRATORS

A Simple Alternative to ICE Water!

As part of your HACCP Program, use Tel-Tru Check-Temp Calibrators to verify the accuracy of your food service thermometers.

Fast, easy to use, and accurate! The Tel-Tru Check-Temp Calibrator allows accurate verification of thermometer accuracy at the temperature point critical to the user's actual application.  School Food Services are using the Check-Temp Calibrator to verify the accuracy of their dial and digital thermometers.

       

The multi-hole Check-Temp Calibrators allow you to verify the accuracy of dial thermometers and digital probes of all sizes.  They fit probes up to .250", .125", .187" and .375" diameter. Single hole Check-Temps fit probes up to .150" diameter. Custom hole diameters and custom temperature points available, please consult factory.

  • Verify the accuracy of dial thermometers and digital probes of all sizes
  • Optional factory re-certification and maintenance program
  • Built-in circuitry to warn if unit is more than 1°F out of calibration
  • Use with Dial Type thermometers - Built-in tool for holding the calibration nut makes adjustments fast and easy
  • Use with Digital Thermometers - Compare actual performance to accuracy specifications
  • Temperature Units - Check and calibrate at your critical temperature point
  • Accessories: Carrying case (padded Cordura® nylon); dial adjustment tool; cleaning brushes; tip sensitive probe adapter

     

     Click on the Picture to download full brochure and specification

       

    The ICE Point and Boiling Points Methods are Difficult? A "Pain" ? Time Consuming?

     

  •                 

  • Order now -

  •  FAX 208-246-7582 ,

  •  Phone 818-825-8167 -

  •  

     

     

     

     

  •  

  • Check-Temp 40160M

  • Check-Temp Cold/Hot Calibrator model 40160M,

    Dual cold and hot calibrator 40 and 160 degrees F setpoint. Multi hole unit fits probes up to .250", .125", .187" and .375". Includes one dial adjustment tool, cleaning brush, and probe adapter.

    Lead Time: 1 to 3 weeks

    Price per unit: $819 


    We will gladly provide a quote for any other Tel-Flu Check-Temp Calibrator. Go to http://www.teltru.com , select you requested Tel-Tru products, and ask us for a quote.




  • Learn more about manual thermometer calibration as appears on the University of Nebraska website:

     
  •  

  • Thermometer Calibration

    HACCP based food safety programs require accurate record keeping to be successful. Temperature is often the parameter of interest when monitoring a critical control point (CCP). To assure that a temperature dependant process is under control a calibrated thermometer must be used to record temperatures. The majority of thermometers can be calibrated following a few basic procedures.

    To be considered accurate, a thermometer must be calibrated to measure within +/- 2° F (1.1° C) of the actual temperature. Actual temperature can be determined in a variety of ways including measurement with an NIST (National Institute of Standards and Technology) certified reference thermometer or simply through using an ice water solution or boiling water. Another option is the use of sophisticated, and often high cost, calibration equipment that is increasingly becoming available commercially.

    The simplest and cheapest way to calibrate a thermometer is through either the use of ice water or boiling water. Distilled water should always be used as dissolved solutes in tap water can significantly affect both freezing and melting points. Another important consideration is the altitude (Table 1) at which calibration is being performed. At sea level, pure water boils at 212° F but at 10,000 feet above sea level it boils at only 194° F. Barometric pressure also has an effect on boiling point but the effect is much less than that of altitude.

    You may visit WorldAtlas.com to determine the altitude of your city.

    Thermometers intended for measuring higher temperature items, such as cooked product, should be calibrated in boiling water while those used for taking lower temperatures should be calibrated in ice water. When calibrating in ice water both the water and ice should be composed of distilled water. In either case care should be taken to prevent the thermometer from contacting the container being used as this could result in erroneous temperature readings.

    Calibration in Ice Water

      1. Add crushed ice and distilled water to a clean container to form a watery slush.
      2. Place thermometer probe into slush for at least one minute taking care to not let the probe contact the container.
      3. If the thermometer does not read between 30° and 34° F adjust to 32° F. Non-adjustable thermometers should be removed from use until they have been professionally serviced.

    Calibration in Boiling Water

      1. Bring a clean container of distilled water to a rolling boil.
      2. Place thermometer probe into boiling water for at least one minute taking care not to let the probe contact the container.
      3. If the thermometer does not read between 210° and 214° F adjust to 212° F. Non-adjustable thermometers should be removed from use until they have been professionally serviced.

    Thermometers that are found to be inaccurate (i.e. do not measure within +/- 2°F of the actual temperature) should either be manually adjusted or serviced by a professional. Thermometers that have a history of deviating from actual temperature measurements should be discarded and replaced. To assure accuracy, NIST certified thermometers must be re-certified annually.

    Thermometers that cannot be easily calibrated through direct immersion in boiling or ice water can be calibrated by comparing readings with another calibrated thermometer. Thermometers that may be calibrated in this way include smokehouse probes and room temperature thermometers. When doing this it is important that the thermometer used for the comparison has been calibrated recently. All thermometers should be calibrated regularly with those used for monitoring CCP's being calibrated either daily or weekly, depending on the volume of your operations. Any thermometer that has been subjected to abuse, such as being dropped on the floor, should be immediately recalibrated to assure accuracy. Hard to calibrate thermometers could be compared directly with NIST reference thermometers but this may be undesirable as many of these reference thermometers are glass and mercury and could present chemical and physical hazards in food production areas.

    Table 1 - Relationship of Altitude to Boiling Point of Pure Water

    Feet Above Sea Level
    Boiling Point
    Feet Above Sea Level
    Boiling Point
    0
    212° F
    4,500
    203° F
    500
    211° F
    5,000
    203° F
    1,000
    210° F
    6,000
    201° F
    1,500
    209° F
    7,000
    199° F
    2,000
    208° F
    8,000
    197° F
    2,500
    207° F
    10,000
    194° F
    3,000
    206° F
    12,000
    190° F
    3,500
    205° F
    14,000
    187° F
    4,000
    204° F

     

     

     

     

     

    Green Edge Systems, Inc., is a trusted leader in Technology Solutions for School Food Services that include HACCP wireless temperature monitoring and food safety solutions, state-of-the-art affordable hardware products, software and communication platforms, humidity refrigeration control, Digital Menu Boards and Thermometer Calibrators. The product line includes the FreshLoc HACCP wireless temperature monitoring system, the PAR Tech iQuality Web Based Rugged HACCP Hand Held PDA Inspection System, the Epicure Digital Menu Boards, the HumiFilter humidity cooler filters and the Tel-Tru Thermometer Calibrators. These systems provide key elements for implementing the required HACCP food safely that ensures food safely and substantial saving for school food services and efficient and modern operation of School Food Services.
     
    To get additional information on the FreshLoc HACCP Wireless Temperature Monitoring Systems for Food Services, the PAR Tech iQuality Web Based Rugged HACCP Hand Held
    PDA Inspection System, the Epicure Digital Menu systems, the HumiFilters Humidity Cooler Filters and the Tel-Tru Thermometer Calibrators or to set up a meeting and demonstration, contact Green Edge Systems.

    Contact:
    mailto@tommy.orpaz@greenedgesystems.com

    http://www.thermometercalibrators.com

    818-825-8167

     

     

     

     

     

     

  •  

    Web Hosting Companies